Abstract
Background: Flow cytometry has been applied successfully to the sizing of medium to large-sized DNA molecules, thanks to the excellent staining properties of cyanine chromophores such as TOTO (homodimer of thiazole orange) (Petty et al.: Anal Chem 67:1755-1761, 1995). The hydrodynamic flow, used to focus the sample molecules in a small laser-illuminated volume, is also responsible for their alignment, thereby allowing the determination of the TOTO-dipole orientation with respect to the DNA axis (Agronskaia et al.: Appl Opt 38:714-719, 1999). - Methods: We present model calculations of the fluorescence yield of TOTO-stained DNA measured in a flow-cytometric setup with high numerical aperture. The models consider different orientations of the chromophore dipoles. - Results: Comparison of measurement and calculation suggests that the absorption dipoles of the TOTO molecule make a mean angle of 61° with the helix axis of the DNA molecule. This mean angle can be the consequence of two binding modes. - Conclusions: Our results indicate that any model with a significant contribution of perpendicularly-oriented chromophores fails to reproduce the experimental results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.