Abstract

This study reports thermal performance of a shrouded 348mm×558mm aluminum plate-fin heat sink subject to various input powers and orientations. Effects of clearance (C) and the orientation on the heat transfer of the heat sink were investigated. Results show that the clearance effect is detectable only in a “window region” between 5mm and 10mm where an appreciable rise of heat transfer coefficient is encountered. As the tilted angle (θ) of the LED panel is increased, the heat transfer coefficient is reduced and the clearance effect on heat transfer becomes more pronounced. The heat transfer coefficients are similar between two cases in which the tilted angles of the LED panel are supplementary irrespective of clearance and input power. Except the cases of a horizontal heat sink, heat transfer coefficient of the shrouded heat sink having a fin array facing downward is usually slightly higher than that having supplementary tilted angle.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.