Globalization has resulted in pollution, carbon emissions, climate change, and an insufficient supply of natural resources. As a result, research is required to increase the thermal performance of buildings. In this regard, using a courtyard as a building component is one of the most sustainable ways to improve the building's thermal performance and microclimate. While utilizing the Envi-met program on the configurations chosen for the fully enclosed courtyard, this study investigated the effect of orientation on the fully enclosed courtyard's thermal performance. 1:1:1 and 1:2:1 are examples of this setup. The orientations considered in this example were N-S, E-W, NE-SW, and NW-SE. The air temperature, mean radiant temperature and physiological equivalent temperature were measured during simulations of two configurations of the fully enclosed courtyard. According to the research, the air temperature, mean radiant temperature and physiological equivalent temperature rises as the size of the courtyard grows. As a result, the air temperature in the 1:1:1 courtyard arrangement is lower than in the 1:2:1 courtyard design.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.