Abstract

The aim of the study is the activity concentration measurements of organic and inorganic 14C in the discharges of JSC “Institute of Nuclear Materials” (INM). In INM the research water-water reactor “IVV-2M” is operating. Collecting of 14C species was performed using a 14C sampler with a chromium oxide and platinum catalysts at different temperatures: 400, 550 and 700 °C. The measurements of 14C activity were performed using a liquid scintillation counter. The share of organic 14C in emissions ranged from 0.30 to 0.84 and depends on the temperature of the catalyst, core structure and reactor operating mode.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.