Abstract
The purpose of this study was to evaluate the differences in the organ doses and the effective doses using three types of automated organ dose estimation software for low-dose computed tomography (CT) screening for lung cancer and to evaluate the correlations between each dose and size-specific dose estimates (SSDEs). Seventy-two adults who underwent low-dose CT screening for lung cancer were included, and the organ doses and the effective doses were calculated using each of automated organ dose estimation software. We evaluated differences between software for the organ doses and the effective doses and the correlations between each dose and SSDEs. Differences in organ doses and effective doses were observed among the software. The organ doses showed a strong correlation (r=0.833-0.995) with SSDEs for organs within the scan range. The effective doses showed a strong correlation (r=0.830-0.970) with SSDEs, although there were significant differences among the software. Although the organ doses and the effective doses differed between software, it may be possible to estimate them from SSDEs by using linear regression equations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.