Abstract

Detection of wooden foreign bodies within the orbit can be difficult on imaging, including computed tomography (CT). When visible, wood appears iso- or hypodense and can mimic air or fat. We report the case of a 3-year-old boy with progressive orbital cellulitis following a penetrating wood injury to the right lower lid. CT imaging revealed a linear hyperdensity contiguous with an orbital abscess. He underwent a right anterior orbitotomy with abscess drainage, during which exploration revealed a 2.3cm retained wooden foreign body. The appearance of wood as hyperdense on imaging is unusual. In the appropriate context, high clinical suspicion for retained wood should be maintained with any irregularity on CT imaging.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.