Abstract
To report the efficacy of percutaneous treatment of an orbital venous malformation with an electrolytically detachable fibred coil. We report an instance of radiography-guided percutaneous treatment with an electrolytically detachable fibred coil in a 16-year-old boy with acute, spontaneous, painless proptosis on the left side, which progressed with time. Magnetic resonance imaging, angiography and orbitophlebography revealed a low-flow, intraorbital venous malformation. Percutaneous puncture and drainage were followed by a short remission. Following an acute recurrence, a single detachable fibred coil was deployed via a percutaneous approach under angiographic guidance. No radiological or clinical recurrences were observed over 4 years. Embolization of a deep orbital venous malformation with detachable fibred coils via a percutaneous approach can be highly effective, and may be considered before proceeding with open surgery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.