Abstract

BackgroundStudies show that the therapeutic CPAP pressure is associated with oral appliance (OA) treatment outcome in obstructive sleep apnea (OSA) patients. However, these studies included either CPAP adherent patients using fixed pressure devices, or partly CPAP non-adherent patients using fixed pressure or auto-adjusting (auto-CPAP) devices. In many countries, auto-CPAP is predominately used, and only those non-adherent to therapy need a change to OA. Therefore, studies examining the relationship between CPAP pressures and OA treatment outcome should focus on patients non-adherent to auto-CPAP.PurposeThe purpose of this paper is to assess if CPAP pressures predicted OA treatment outcome in patients non-adherent to auto-CPAP therapy.MethodsThe OA treatment responders and non-responders were defined by two success criteria ((1) AHI < 5; (2) 5 ≤ AHI < 10 and > 50% AHI reduction). Logistic regression analyses were performed for CPAP pressures and baseline variables. ROC curve analyses were used to identify CPAP pressure cutoff values, alone and combined with other explanatory variables, predicting the OA treatment outcome.ResultsEighty-seven patients with moderate or severe OSA were included. Maximum CPAP pressures (CPAPmax) were higher in non-responders by both criteria and were, together with baseline AHI, associated with the OA treatment outcome in multivariate regression analyses. ROC curves identified an optimal CPAPmax cutoff of 12 cm H2O, corresponding to a positive predictive value (PPV) of 0.85 in predicting non-response using criterion 1. A prediction model combining CPAPmax > 12 and baseline AHI ≥ 30 had a PPV of 1.0 for non-response by both criteria.ConclusionsMaximum CPAP pressure was a moderate predictor of OA treatment outcome, but combined with baseline AHI, the ability to identify OA non-responders was high.

Highlights

  • Obstructive sleep apnea (OSA) is a common condition in which the upper airways intermittently collapse during sleep, causing partial or total cessation of airflow

  • Background Studies show that the therapeutic Continuous positive airway pressure (CPAP) pressure is associated with oral appliance (OA) treatment outcome in obstructive sleep apnea (OSA) patients

  • Studies examining the relationship between CPAP pressures and OA treatment outcome should focus on patients non-adherent to auto-CPAP

Read more

Summary

Introduction

Obstructive sleep apnea (OSA) is a common condition in which the upper airways intermittently collapse during sleep, causing partial or total cessation of airflow This results in fragmentation of sleep and oxygen desaturations and is associated with neurocognitive impairment and an increased risk of cardiovascular disease and all-cause mortality [1, 2]. CPAP pressure is associated with oral appliance (OA) treatment outcome in obstructive sleep apnea (OSA) patients. These studies included either CPAP adherent patients using fixed pressure devices, or partly CPAP non-adherent patients using fixed pressure or auto-adjusting (auto-CPAP) devices. Studies examining the relationship between CPAP pressures and OA treatment outcome should focus on patients non-adherent to auto-CPAP. Purpose The purpose of this paper is to assess if CPAP pressures predicted OA treatment outcome in patients nonadherent to auto-CPAP therapy

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.