Abstract

A 3D unsteady numerical simulation of a reheating furnace was performed to obtain the optimal slab residence time. Too long residence time decrease the efficiency of the reheating furnace, whereas too short residence time cannot satisfy the required heating quality of a slab. The total five cases of residence times – 6032s, 6496s, 6960s, 7424s and 7888s – were investigated for the optimum residence time analysis with the two slab requirements, those of emission temperature and uniformity. In this study, the slab emission temperature should be in the range between 1373K and 1573K. The skid mark severity of an emitted slab should be lower than 50K to satisfy the uniformity requirement. The numerical analysis was done for the identical geometry and operating condition of the reheating furnace using FLUENT. Slabs were assumed to move very quickly that it took no time for them to move next positions. The quick movements of slabs were processed with the own developed User-Defined Function program. Among the five cases of residence times, the residence time of 7427s turned out to be most efficient.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.