Abstract

AbstractThe continuum model constitutes a simple and efficient tool to analyze high-rise wall-frame buildings. It has been commonly used in recent decades to analyze the behavior of these structures. The related equations are revisited to study the effect of the calculation precision on the determination of the optimum level of wall curtailment. The results obtained illustrate the influence of calculation precision in specifying the optimum level of wall curtailment. The relationship between the curtailment level and the resulting internal forces is investigated. The level of curtailment which results in the minimum top deflection of the structure eliminates, at the same time, the negative moments and negative shear forces in the wall.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.