Abstract
ABSTRACTA method for determining time–optimum fluid temperature changes is presented. In contrast to current standards, stepwise fluid temperature changes are allowed. The optimum fluid temperature changes are assumed in the form of a simple time function. It is possible to increase the fluid temperature stepwise, and then the fluid temperature can be increased with a constant rate at the beginning of the heating process. The permissible rates of the fluid temperature change determined by the proposed method are smaller than those obtained by boiler standards. But, due to the abrupt increase in fluid temperature, the heating time of a thick-walled component is of the same order as in the case of calculations according to EN 12952-3 European Standard. However, the total circumferential stresses on the edge of the hole do not exceed the allowable value.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.