Abstract
The flue gas which resulted from oxidation of the fuel flow in the SOFC stack was burnt off in the catalytic combustor under the operating condition acquired by the process simulation. Conversion of the combustible components in the stack flue gas was experimentally measured at four different GHSVs in a tubular reactor packed with base-metal catalyst pellets. Optimum GHSV of 6,990 hr-1 in the catalytic combustor was determined on the basis of reactor performance including pressure drop, carbon monoxide slip, and conversion of the combustible components.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.