Abstract
In this communication, a transient analysis of a transwall for an air-conditioned room is presented. An analytical expression for the thermal flux entering the air-conditioned room through direct and indirect gain is derived in terms of the physical properties of the transwall as well as the climatic parameters. The water temperatures and the flux entering the room are computed on an hourly basis for a number of days for the typical cold climatic conditions of Srinagar. On the basis of the numerical results, it is observed that: (i) steady-state conditions are acheived after the third day; and (ii) the maximum thermal flux is achieved for δL = δL w1/ δL w = 1.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.