The multi-axis force sensor (MFS) has been extensively adopted in humanoid robot foot to obtain external forces/moments acted on the foot while in locomotion. The precision and comprehensive performances of MFS originally determined by its elastomer structure are significant essentially for humanoid robots to keep balance by detection of external forces/moments during walking motion. The reason for the transmission of coupling-error of structure is analyzed and then the optimum method for the function of objective-optimization of MFS compliance matrix, Finite Element Method (FEM), orthogonal design and range analysis method are all proposed synthetically. In addition, the comprehensive performances of MFS designed by the optimum method are analyzed and elaborated in a concrete design case. Finally, the main indexes of the MFS are verified experimentally through humanoid robot’s dynamic walking motion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.