Abstract

Compared with the traditional cable, the high-temperature superconducting (HTS) cable has the advantages of low loss and large capacity transmission. At present, the research on HTS cables mainly focuses on the calculation of AC loss, the performance under specific working conditions and cooling system design. Relatively little research has been carried out on the basic design and overall layout optimization of the cables. In this paper, an HTS cable with a rated current of 4 kA was designed. Firstly, according to the selected superconducting cable parameters, the body design of cables with different structures was carried out and the corresponding finite element models were built. Then, the performance analysis of HTS cables with different layouts was carried out based on the proposed cable performance evaluation indicators and the CORC double-layer structure was determined as the scheme of this cable. Finally, the AC loss of the cable with this topology was calculated to be 9.81 J/m under rated conditions. The cooling system can ensure the safe operation of the cable in the rated temperature range.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call