Abstract

Cooling channel design is important in mould designs to achieve shorter cycles, dimensional stability and reduced part stresses. Traditionally, cooling channels have been machined into mould components to avoid interference with the ejection system, coring, cavity and other mould details. Over the years straight drilled cooling channels have given away, in part, to conformal cooling technique often using free form fabrication techniques. This paper presents a study of optimised mould design with conformal cooling channel using finite element analysis. Various configurations of conformal cooling channels have been developed. The part cooling time using the conformal cooling channels and the straight cooling channels in the mould are computed using the Pro/Mechanica Thermal FEA software. Results are presented based on temperature distribution and cooling time using steady state and transient analysis conditions. The results show a reduction in cycle time for the plastic part with conformal cooling channel design.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.