Abstract

The purpose of this study is to evaluate layer fusion options for deep learning classification of optical coherence tomography (OCT) angiography (OCTA) images. A convolutional neural network (CNN) end-to-end classifier was utilized to classify OCTA images from healthy control subjects and diabetic patients with no retinopathy (NoDR) and non-proliferative diabetic retinopathy (NPDR). For each eye, three en-face OCTA images were acquired from the superficial capillary plexus (SCP), deep capillary plexus (DCP), and choriocapillaris (CC) layers. The performances of the CNN classifier with individual layer inputs and multi-layer fusion architectures, including early-fusion, intermediate-fusion, and late-fusion, were quantitatively compared. For individual layer inputs, the superficial OCTA was observed to have the best performance, with 87.25% accuracy, 78.26% sensitivity, and 90.10% specificity, to differentiate control, NoDR, and NPDR. For multi-layer fusion options, the best option is the intermediate-fusion architecture, which achieved 92.65% accuracy, 87.01% sensitivity, and 94.37% specificity. To interpret the deep learning performance, the Gradient-weighted Class Activation Mapping (Grad-CAM) was utilized to identify spatial characteristics for OCTA classification. Comparative analysis indicates that the layer data fusion options can affect the performance of deep learning classification, and the intermediate-fusion approach is optimal for OCTA classification of DR.