Abstract
BackgroundThe number of prostate biopsy cores that need to be taken from each magnetic resonance imaging (MRI) region of interest (ROI) to optimize sampling while minimizing overdetection has not yet been clearly elucidated. ObjectiveTo characterize the incremental value of additional MRI-ultrasound (US) fusion targeted biopsy cores in defining the optimal number when planning biopsy and to predict men who might benefit from more than two targeted cores. Design, setting, and participantsThis was a retrospective cohort study of MRI-US fusion targeted biopsies between 2015 and 2017. InterventionMRI-US fusion targeted biopsy in which four biopsy cores were directed to each MRI-targeted ROI. Outcomes measurements and statistical analysisThe MRI-targeted cores representing the first highest Gleason core (FHGC) and first clinically significant cancer core (FCSC; GS≥3+4) were evaluated. We analyzed the frequency of FHGC and FCSC among cores 1–4 and created a logistic regression model to predict FHGC >2. The number of unnecessary cores avoided and the number of malignancies missed for each Gleason grade were calculated via clinical utility analysis. The level of agreement between biopsy and prostatectomy Gleason scores was evaluated using Cohen's κ. Results and limitationsA total of 479 patients underwent fusion targeted biopsy with four individual cores, with 615 ROIs biopsied. Among those, FHGC was core 1 in 477 (76.8%), core 2 in 69 (11.6%), core 3 in 48 (7.6%), and core 4 in 24 men (4.0%) with any cancer. Among men with clinically significant cancer, FCSC was core 1 in 191 (77.8%), core 2 in 26 (11.1%), core 3 in 17 (6.2%), and core 4 in 11 samples (4.9%). In comparison to men with a Prostate Imaging-Reporting and Data System (PI-RADS) score of 5, patients were significantly less likely to have FHGS >2 if they had PI-RADS 4 (odds ratio [OR] 0.287; p=0.006), PI-RADS 3 (OR 0.284; p=0.006), or PI-RADS 2 (OR 0.343; p=0.015). Study limitations include a single-institution experience and the retrospective nature. ConclusionsCores 1–2 represented FHGC 88.4% and FCSC 88.9% of the time. A PI-RADS score of 5 independently predicted FHGC >2. Although the majority of cancers in our study were appropriately characterized in the first two biopsy cores, there remains a proportion of men who would benefit from additional cores. Patient summaryIn men who undergo magnetic resonance imaging-ultrasound fusion targeted biopsy, the first two biopsy cores diagnose the majority of clinically significant cancers. However, there remains a proportion of men who would benefit from additional cores.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.