Abstract
Small molecular imaging probes are often found to be rapidly cleared from the circulation. In order to improve signal to noise ratio (SNR) by high probe accumulation in the target tissue we intended to prolong the presence of the probes in the circulation by exploiting inherent transport mechanisms. Human serum albumin (HSA) is playing an increasingly important role as a drug carrier in clinical settings and drugs directly bound to albumin or attached to albumin binding moieties have been successfully developed for treatment approaches. To optimize the bioavailability of existing fluorescent probes, a hydrophobic affinity tag is installed, which enhances albumin binding. In a first experiment an endothelin-A receptor (ETAR) probe is modified by inserting a trivalent linker, attaching an albumin affinity tag and labeling the conjugate with the fluorescent dye Cy 5.5. The spectroscopic properties of the conjugate are examined by photometer- and fluorometer measurements in comparison to a probe without albumin binding tag. Albumin binding was proven by agarose gel electrophoresis. The affinity towards ETAR was confirmed in vitro by cell binding assays on human fibrosarcoma cells (HT-1080) and in vivo by murine xenograft imaging studies. In vitro, the modified probe retains high target binding in the absence and presence of albumin. Binding could be blocked by predosing with ETAR antagonist atrasentan, proving specificity. The in vivo examinations in comparison to the established probe showed a reduced renal elimination and a prolonged circulation of the tracer resulting in significantly higher signal intensity (SI) at the target and a higher signal-to-noise ratio (SNR) between 3h and 96h after injection. In summary, we designed a small molecular, non-peptidic fluorescent probe which targets ETAR and reversibly binds to serum albumins. The reversible binding to albumin enhances the biological half-life of the probe substantially and enables near infrared optical imaging of subcutaneous tumors for several days. This approach of reversibly attaching probes to serum albumin may serve as a tool to optimize tracer distribution for more precise target characterization in molecular imaging experiments.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.