Abstract

This study aimed to determine the optimal bandpass filter (BPF) setting for acoustic stimuli in recording the ocular vestibular-evoked myogenic potential (oVEMP). Twelve healthy volunteers underwent oVEMP tests using acoustic stimuli with various high-pass filters (1, 10 and 100Hz) and low-pass filters (500, 1000 and 2000Hz). Initially, various effects of high-pass filter on the oVEMPs were examined under Conditions A (BPF of 1–1000Hz), B (BPF of 10–1000Hz) and C (BPF of 100–1000Hz). Of these conditions, Condition A showed 100% response rate and had larger nI–pI amplitude than Conditions B and C. Thus, Condition A was selected for subsequent analysis of the various effects of low-pass filter on the oVEMPs. However, Condition A (BPF of 1–1000Hz) did not significantly differ from Conditions D (BPF of 1–500Hz) and E (BPF of 1–2000Hz) in terms of the latencies and amplitudes of oVEMPs. Condition A thus is supposed to be the optimal recording condition for oVEMPs. In conclusion, the optimal BPF setting for acoustic stimuli in recording oVEMPs is suggested to be between 1 and 1000Hz.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.