Abstract

Energy that can be obtained from natural resources and constantly replenished by nature is called “renewable energy”. To harness solar energy and convert it into electricity, a device known as a solar panel is utilized. However, solar panels encounter certain drawbacks, including reduced efficiency as the panel temperature rises and the partial absorption of sunlight due to its reflection by the top glass layer. This study aims to optimize solar panel efficiency by innovatively integrating a cooling system with water treatments and an aluminum foil reflector to enhance energy output. The study focused on a 700 mm × 510 mm × 30 mm monocrystalline solar panel. Initial efficiency improved significantly after implementing the cooling and reflector system. Based on measurement data, incorporating the reflector, revealed an average temperature of 61.3°C and solar radiation of 871.10 W/m². The cooling duration of 40.64 seconds was achieved with a water pump flow rate of 0.29 lt/s. Notably, the combined approach yielded substantial efficiency enhancements, with the solar panel reaching peak efficiency levels of 10.36%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.