Abstract

Personalized medicine has exposed wearable sensors as new sources of biomedical data which are expected to accrue annual data storage costs of approximately $7.2 trillion by 2020 (>2000 exabytes). To improve the usability of wearable devices in healthcare, it is necessary to determine the minimum amount of data needed for accurate health assessment. Here, we present a generalizable optimization framework for determining the minimum necessary sampling rate for wearable sensors and apply our method to determine optimal optical blood volume pulse sampling rate. We implement t-tests, Bland-Altman analysis, and regression-based visualizations to identify optimal sampling rates of wrist-worn optical sensors. We determine the optimal sampling rate of wrist-worn optical sensors for heart rate and heart rate variability monitoring to be 21-64 Hz, depending on the metric. Determining the optimal sampling rate allows us to compress biomedical data and reduce storage needs and financial costs. We have used optical heart rate sensors as a case study for the connection between data volumes and resource requirements to develop methodology for determining the optimal sampling rate for clinical relevance that minimizes resource utilization. This methodology is extensible to other wearable sensors.

Highlights

  • Personalized medicine has exposed wearable sensors as new sources of biomedical data which are expected to accrue annual data storage costs of approximately $7.2 trillion by 2020 (>2000 exabytes)

  • Up to 80% of health data collected in clinics is considered unusable because it is spread across numerous repositories and cannot be linked to the electronic health record (EHR) [3]

  • We determined that the optimal sampling rate for a wrist-worn wearable device optical heart rate sensor for all HR and heart rate variability (HRV) metrics is 64 Hz

Read more

Summary

Introduction

Personalized medicine has exposed wearable sensors as new sources of biomedical data which are expected to accrue annual data storage costs of approximately $7.2 trillion by 2020 (>2000 exabytes). We have used optical heart rate sensors as a case study for the connection between data volumes and resource requirements to develop methodology for determining the optimal sampling rate for clinical relevance that minimizes resource utilization. This methodology is extensible to other wearable sensors. The practice of personalized medicine, including the combination of clinical, genomics, imaging, wearables, and “real-world” data, has the potential to revolutionize healthcare. This rapidly growing digital health trace poses significant challenges in healthcare data management [1]. In addition to expanding medical storage capabilities, efficiency, usability, and compute power, we must determine how to trim data volumes appropriately to retain important information while removing unnecessary or repetitive information

Objectives
Methods
Results
Discussion
Conclusion
Full Text