Abstract

Positive end-expiratory pressure (PEEP) is a crucial component of mechanical ventilation to improve oxygenation in critically ill patients with respiratory failure. The interaction between abdominal and thoracic compartment pressures is known well. Especially in intra-abdominal hypertension, lower PEEP may cause atelectotrauma by repetitive opening and closing of alveoli. In this study, it was aimed to investigate the effect of PEEP adjustment according to the intra-abdominal pressure (IAP) on oxygenation and clarify possible harms. Patients older than 18 were mechanically ventilated due to hypoxemic respiratory failure and had normal IAP (<15 mmHg) included in the study. Patients with severe cardiovascular dysfunction were excluded. The following PEEP levels were applied: PEEPzero of 0 cmH2O, PEEPIAP/2 = 50% of IAP, and PEEPIAP = 100% of IAP. After a 30-minute equilibration period, arterial blood gases and mean arterial pressures were measured. One hundred thirty-eight patients (mean age 66.5 ± 15.9, 56.5% male) enrolled on the study. The mean IAP was 9.8 ± 3.4. Seventy-nine percent of the patients' PaO2/FiO2 ratio was under 300 mmHg. Figure 1 shows the change in PaO2/FiO2 ratio, PaCO2, PPlato, and MAP of the patients according to the PEEP levels. Overall increases were detected in the PaO2/FiO2 ratio (P < 0.001) and Pplato (P < 0.001), while PaCO2 and MAP did not change after increasing PEEP gradually. Pairwise analyses revealed differences in PaO2/FiO2 between PEEPzero (186.4 [85.7-265.8]) and PEEPIAP/2 (207.7 [101.7-292.9]) (t = -0.77, P < 0.001), between baseline and PEEPIAP (236.1 [121.4-351.0]) (t = -1.7, P < 0.001), and between PEEPIAP/2 and PEEPIAP (t = -1.0, P < 0.001). Plato pressures were in the safe range (<30 cmH2O) at all three PEEP levels (PEEPzero = 12 [10-15], PEEPIAP/2 = 15 [13-18], PEEPIAP = 17 [14-22]). In patients with acute hypoxemic respiratory failure and mechanically ventilated, PEEP adjustment according to the IAB improves oxygenation, especially in the settings of the limited source where other PEEP titration methods are absent.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.