Abstract

A micro-pressure wave (MPW) is radiated from the tunnel exit when a train enters a tunnel at high speed. The MPW causes infrasound and audible noise near the tunnel portal; hence, it must be reduced for environmental reasons. A hood with openings is a typical countermeasure. The openings must be suitably distributed to effectively reduce the MPW. The optimum distribution depends on the shape of the train nose and its velocity; therefore, it needs to be readjusted, and the hood sometimes needs to be extended when the train velocity increases or a new type train is put into operation. This study reports on numerical studies and model experiments to investigate the effective composition of an unvented hood because such a hood would eliminate the need to adjust the distribution of the openings according to the train characteristics. The results show that the optimum cross-sectional area of the hood is 2.6 times the cross-sectional area of the tunnel, and its optimum length is 1.8 times the tunnel diameter when the train velocity is 350 km/h, and the train nose length is three to six times the train radius. Finally, the unvented hood is economically advantageous compared with the currently used hood.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call