Abstract

Response surface methodology (RSM) was used to determine the optimum experimental conditions to extract methylmercury from fish samples for GC analysis. The influence of four variables – acid concentration (3–12 M), cysteine concentration (0.5–2% w/v), solvent volume (3–9 ml) and extraction time (10–30 min) – on recovery of methylmercury was evaluated. The detection limit for methylmercury analysis using a microelectron capture detector was 7 ng g−1 in fish samples. The mean recovery under optimum conditions was 94%. Experimental data were adequately fitted into a second-order polynomial model with multiple regression coefficients (r 2) of 0.977. The four variables had a significant effect (p < 0.05) on the recovery of methylmercury from a reference material (BCR-463). Optimum conditions for methylmercury extraction were found using an acid concentration of 12.2 M, cysteine concentration of 2.4%, solvent volume of 1.5 ml and extraction time of 35 min. The validation of the developed method to analyze methylmercury in fish samples exhibited good agreement with mercury content in the samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.