Abstract
The use of integrated waveguide modulators is a common technique in electric-field sensing. However, the distortion in the modulated signal caused by high half-voltage Vπ and the difficulty in obtaining low-frequency responses are challenging issues for the use of low-frequency alternating-current (AC) electric-field sensors. This study investigates the use of an optimized segmented slot waveguide as the core of a sensor to determine the sensor features that produce useful frequency responses and sensitivity. The segmented slot waveguide is optimized in terms of periodicity and segment width to produce low Vπ and electrical bandwidth before testing the sensor sensitivity. The results show that reducing the segment width achieves a low Vπ of 0.32 V and a very low electrical bandwidth of 4.3 kHz. Our study provides evidence of the feasibility of using a segmented slot waveguide as the primary element for highly sensitive, low-frequency AC electric-field sensors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.