Abstract

Switching circuits, operating at high frequencies, have led to considerable reductions in the size of magnetic components and power supplies. Nonsinusoidal voltage and current waveforms and high-frequency skin and proximity effects contribute to power transformer losses. Traditionally, power transformer design has been based on sinusoidal voltage and current waveforms operating at low frequencies. The physical and electrical properties of the transformer form the basis of a new design methodology while taking full account of the current and voltage waveforms and high-frequency effects. Core selection is based on the optimum throughput of energy with minimum losses. The optimum core is found directly from the following transformer specifications: frequency; power output; and temperature rise. The design methodology is illustrated with a detailed design of a push-pull power converter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.