Abstract

In the paper a standard measurement sequence for INFORM-based sensorless position estimation of permanent magnet synchronous motors is analyzed and its properties with respect to the current deviation before and after the measurement are pointed out. Based on that a modified operating point adjusted measurement sequence with minimum current deviation and minimum time demand is introduced. Measurement results verify the improvement of the modified measurement sequence: The current distortion is reduced significantly resulting in reduced additional losses caused by the INFORM-measurement. Additionally, in the paper several measurement results concerning the performance of the sensorless position estimation under various load conditions are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.