Abstract
The telescope is vital for accurate gravitational wave detection in the TianQin project. It must meet criteria like a geometric tilt-to-length (TTL) coupling noise c o e f f i c i e n t≤0.02√2n m/µr a d and wavefront R M S≤λ/30. Analyzing the pupil aberration's impact on geometric TTL noise, we devised an optimization method using the chief ray spot diagram's standard deviation. Implementing this in Zemax with a ZPL macro, we designed an optical system meeting TianQin's requirements. The system has a maximum geometric TTL noise coefficient of 0.0250nm/µrad over the science FOV and a wavefront RMS of 0.0111λ, confirming the method's feasibility.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.