For cool roofs the combined effect of the three parameters that define heat gain and loss from a roof, namely solar albedo α, thermal emittance E, and sub-roof R-value, must be considered. An accurate contribution of night sky cooling, and hence humidity and total down-welling atmospheric radiation is needed. A systematic analysis of the contribution of a roof to average cooling load per day and to peak load reductions is presented for a temperate climate zone over 6 cooling months using an hour-by-hour analysis. Eighteen 3-parameter sets ( α, E, R) demonstrate the over-riding importance of a high α, while sensitivity to R-value and E drops away as albedo rises. Up-front cost per unit reductions in peak demand or average energy use per day always rises strongly as R rises unless albedo is low. A moderate R∼1.63 is superior to high R unless a roof is dark, or winter heating demand is high. We indicate briefly why the roof typically does not present a dominant influence on average winter heating needs in most temperate zones, enhancing the benefits of cool roofs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.