Abstract
An optimization study of an integrated periodic counter-current chromatography (PCC) process in a monoclonal antibody (mAb) downstream process at lab scale, is presented in this paper. The optimization was based on a mechanistic model of the breakthrough curve in the protein-A capture step. Productivity and resin utilization were the objective functions, while yield during the loading of the capture column was set as a constraint. Different integration approaches were considered, and the effect of the feed concentration, yield and the protein-A resin was studied. The breakthrough curve and the length of the product recovery, which depended on the integration approach, determined the process scheduling. Several optimal Pareto solutions were obtained. At 0.5 mg mL−1 and 99% yield, a maximum productivity of 0.38 mg mL−1 min−1 with a resin utilization of 60% was obtained. On the other hand, the maximum resin utilization was 95% with a productivity of 0.10 mg mL−1 min−1. Due to the constraint of the process scheduling, a lower productivity could be achieved in the integration approaches with higher recovery time, which was more remarkable at higher concentrations. Therefore, it was shown that a holistic approach, where all the purification steps are considered in the process optimization, is needed to design a PCC in a downstream process.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.