Abstract
This study is focused on the efficiency of automated transferring system of packages equipped by variable-frequency drive (VFD) and servo drive motor. It was found that rotation frequency of induction motors and linear speed of servo drive decisively affected the unit efficiency that operates in the periodic mode. The system duty cycle was divided in two separate parts taking into account time spans needed to complete the specific tasks by each separate equipment of the system. In order to reduce the power usage of the system, the duration of each part of cycle was extended. Lowered electricity consumption leads to the extension of each cycle’s stage operating times. Frequencies of motors and linear speed of servo drive motors were optimized depending on cycle stages duration. Optimized frequency and linear speed values were calculated and loaded into motors controllers, and the efficiency of each separate equipment was measured, as well as total efficiency of the system. Experimental system debugging using optimized parameters proved that system efficiency increases up to 60 %, and that is closely matched with calculated values.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.