Abstract

Mouse models of genetic and acquired risk factors for atrial fibrillation (AF) have proven valuable in investigating the molecular determinants of AF. Programmed electrical stimulation can be performed using transesophageal atrial pacing as a survival procedure, thus enabling serial testing in the same animal. However, numerous pacing protocols exist, which complicates the reproducibility. The present protocol aims to provide a standardized strategy to develop model-specific experimental parameters to improve reproducibility between studies. Preliminary studies are performed to optimize the experimental methods for the specific model under investigation, including age at the time of the study, sex, and parameters of the pacing protocol (e.g., mode of pacing and definition of AF susceptibility). Importantly, care is taken to avoid high stimulus energies, as this can cause stimulation of the ganglionic plexi with inadvertent parasympathetic activation, manifested by exaggerated atrioventricular (AV) block during pacing and often associated with artifactual AF induction. Animals demonstrating this complication must be excluded from the analysis.