Abstract

Determination of time-weighted average (TWA) concentrations of volatile organic compounds (VOCs) in air using solid-phase microextraction (SPME) is advantageous over other sampling techniques, but is often characterized by insufficient accuracies, particularly at longer sampling times. Experimental investigation of this issue and disclosing the origin of the problem is problematic and often not practically feasible due to high uncertainties. This research is aimed at developing the model of the TWA extraction process and optimization of TWA air sampling by SPME using finite element analysis software (COMSOL Multiphysics, Burlington, MA, USA). It was established that sampling by porous SPME coatings with high affinity to analytes is affected by slow diffusion of analytes inside the coating, an increase of their concentrations in the air near the fiber tip due to equilibration, and eventual lower sampling rate. The increase of a fiber retraction depth (Z) resulted in better recoveries. Sampling of studied VOCs using 23 ga Carboxen/polydimethylsiloxane (Car/PDMS) assembly at maximum possible Z (40 mm) was proven to provide more accurate results. Alternative sampling configuration based on 78.5 × 0.75 mm internal diameter SPME liner was proven to provide similar accuracy at improved detection limits. Its modification with the decreased internal diameter from the sampling side should provide even better recoveries. The results obtained can be used to develop a more accurate analytical method for determination of TWA concentrations of VOCs in air using SPME. The developed model can be used to simulate sampling of other environments (process gases, water) by retracted SPME fibers.

Highlights

  • Analysis of time-weighted average (TWA) concentrations of volatile organic compounds (VOCs) in outdoor and indoor air is an important part of environmental monitoring programs aiming at chronic exposure or background concentrations

  • The goal of this research was to develop a model for solid-phase microextraction (SPME) with both absorptive and adsorptive fibers located inside a protecting needle using a finite element analysis-based model (COMSOL Multiphysics) and use it to disclose potential sources of inaccuracies in the quantification of time-weighted average concentrations of VOCs in ambient air

  • Modeling using COMSOL Multiphysics software allowed obtaining sampling profiles for benzene (Figure 2)

Read more

Summary

Introduction

Analysis of time-weighted average (TWA) concentrations of volatile organic compounds (VOCs) in outdoor and indoor (occupational) air is an important part of environmental monitoring programs aiming at chronic exposure or background concentrations. Such analysis is commonly conducted using gas chromatography (GC) in combination with various sampling and sample preparation approaches. Most techniques require additional sample preparation and thermal desorption in a separate unit connected to a GC [1]. Solid-phase additional stages stages and/or and/or equipment is is based onon sampling viavia thethe passive. VOCs extraction by a additional equipment[2]. [2].It It based sampling passive. VOCs extraction fiber coating retracted inside a protecting needle followed by thermal desorption inside a GC by a fiber coating retracted inside a protecting needle followed by thermal desorption inside a GC injectionport port[3,4]

Objectives
Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.