One option to mitigate the adverse effect of power plant output loss from adding a CO2 capture plant is to operate it in flexible modes in which the capture level and/or regeneration rate are dynamically varied in response to varying electricity market demand and price. This can help the plant meet peak electricity demand and improve its overall profit. However, the benefit is offset by higher capital costs and/or CO2 emission penalty. Various modes of flexible operation including capture level reduction and solvent storage have been optimized for a given post-combustion capture system with typical daily electrical energy price patterns and the results are compared with those from a fixed point operation. Effects of varying storage capacities and energy price patterns have also been evaluated. Simultaneous use of the two flexible modes is also optimized and the result showed significantly higher cost savings compared to the individual uses.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.