Abstract

In polymer gel dosimetry, Magnetic Resonance Imaging (MRI) provides the spin-spin relaxation rate R2=1/T2 image data, which in turn is correlated with the absorbed dose in the irradiated gel dosimeter. The aim of this work is to compare two different mathematical models in determining R2, in terms of precision namely: i) the routinely applied conventional linear regression fitting model, and ii) a new weighted fitting model, which is based on the random noise figure applied for each signal of the T2 decay curve. To investigate the precision of the above models over a wide range of T2 values we have manufactured VIPAR gels with varying gelatine content and irradiated them to known doses.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.