Abstract

New treatments against osteoporosis require testing in animal models and the mouse tibia is among the most common studied anatomical sites. In vivo micro-Computed Tomography (microCT) based micro-Finite Element (microFE) models can be used for predicting the bone strength non-invasively, after proper validation against experiments. The aim of this study was to evaluate the ability of different microCT-based bone parameters and microFE models to predict tibial structural mechanical properties in compression. Twenty tibiae were scanned at 10.4 μm voxel size and subsequently tested in uniaxial compression at 0.03 mm/s until failure. Stiffness and failure load were measured from the load-displacement curves. Standard morphometric parameters were measured from the microCT images. The spatial distribution of bone mineral content (BMC) was evaluated by dividing the tibia into 40 regions. MicroFE models were generated by converting each microCT image into a voxel-based mesh with homogeneous isotropic material properties. Failure load was estimated by using different failure criteria, and the optimized parameters were selected by minimising the errors with respect to experimental measurements. Experimental and predicted stiffness were moderately correlated (R2 = 0.65, error = 14% ± 8%). Normalized failure load was best predicted by microFE models (R2 = 0.81, error = 9% ± 6%). Failure load was not correlated to the morphometric parameters and weakly correlated with some geometrical parameters (R2 < 0.37). In conclusion, microFE models can improve the current estimation of the mouse tibia structural properties and in this study an optimal failure criterion has been defined. Since it is a non-invasive method, this approach can be applied longitudinally for evaluating temporal changes in the bone strength.

Highlights

  • Osteoporosis and osteoarthritis are the most common chronic diseases of the musculoskeletal system

  • All details about the correlations between bone mechanical properties and the morphometric or densitometric properties computed from the micro-Computed Tomography (microCT) images or the predicted structural properties estimated from micro-Finite Element (microFE) models are reported in Appendix A

  • The tibia stiffness was best predicted by microFE models, while weak or no correlations were found with other parameters

Read more

Summary

Introduction

Osteoporosis and osteoarthritis are the most common chronic diseases of the musculoskeletal system. In preclinical studies the strength of the mouse tibia is commonly measured using three-point bending tests (Jepsen et al, 2015), which presents a number of limitations These tests are invasive and they can only be performed ex vivo in cross-sectional experiments, which are associated to the usage of a large number of animals. Three-point bending is not representative of the physiological loading conditions, which would be better replicated by compressive tests (Holguin et al, 2013) This testing approach is affected by experimental artifacts, mainly due to the fact that the aspect ratio of the tibia is low and its cross-section is not constant along the longitudinal direction (Wallace et al, 2014).

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call