Abstract

An optimization design has been developed for radiation shielding of the 13 MeV DECY-13 cyclotron using K-500 concrete, paraffin, and lead. The optimization of shielding was done by calculation of K-500 concrete thickness, paraffin, and lead in order to reduce the equivalent dose rate outside the shielding walls of 1 μSv/hour. The neutron and gamma TVL’s of each material and the thickness of shielding walls was calculated using Monte Carlo method by PHITS computer code. From this calculation, it was obtained that a shielding design of DECY-13 cyclotron with the first layer is 42 cm thick of paraffin, the second layer is 100 cm of K-500 concrete, and an 18 cm thickness of lead as a target chamber hood shielding. This result shows that the DECY-13 shielding design was optimized using K-500 concrete, paraffin, and lead which is able to reduce the concrete thickness from previous design of 170 cm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.