Abstract

Helicon plasma source is being developed at the Budker Institute of Nuclear Physics SB RAS, Novosibirsk. The parameters are studied of the plasma confined in a mirror trap configuration of the magnetic field at an operating frequency of 13.56 MHz. For matching the antenna impedance and generator load, the Π-type matching box was designed and successfully tested at powers of 20–25 kW. The low reflected power (1–2%) was obtained, as compared to that for the L-type matching network used previously (the reflected power was more than 15% at the generator output power of 18 kW). The triple Langmuir probe is used to determine the plasma density. The plasma resistive characteristics were determined using the Rogowski coil measuring the RF antenna current. In the experiments, the plasma with a density of ∽5⋅1012 cm-3 and an electron temperature on axis of 10 eV was obtained, and the RF power transfer efficiency was ∽85% at the RF power of 25 kW.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.