<span>The optimization of thermal column collimator has been studied which resulted epithermal neutron beam for in vivo and in vitro trials of Boron Neutron Capture Therapy (BNCT) at Kartini Research Reactor of 100 kW by means of </span><em>Monte Carlo N-Particle Extended </em><span>(MCNP-X) codes. The design criteria were based on recommendation from the International Atomic Energy Agency (IAEA). MCNP-X calculations indicated by using 5 cm thickness of Ni as collimator wall, 30 cm thickness of Al as moderator, 20 cm thickness of 60Ni as filter, 2 cm thickness of Bi as γ-ray shielding, 3 cm thickness of 6Li2CO3-polyethylene as beam delimiter, and for in vivo in vitro trials purpose, aperture was designed 8 cm radius size, an epitermal neutron beam with an intensity 1.13E+09 n.cm-2.s-1, fast neutron and γ-doses per epithermal neutron of 1.76E-13 Gy.cm2.n-1 and 1.45E-13Gy.cm2.n-1,minimum thermal neutron per epithermal neutron ratio of 0.008,and maximum directionality of 0.73, respectively could be produced. The results have passed all the IAEA’s criteria.</span>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Indonesian Journal of Physics and Nuclear Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.