Abstract
Simple methods for the optimization of ion-exchange chromatography of proteins in our previous papers were applied to cation-exchange chromatography purification of monoclonal antibodies (Mab). We carried out linear gradient elution experiments, and obtained the data for the peak salt concentration and the peak width. From these data, the distribution coefficient as a function of salt concentration, and the height equivalent to a theoretical plate (HETP) as a function of mobile phase velocity were calculated. The optimized linear gradient elution conditions were determined based on the relationship between buffer consumption and separation time. The optimal stepwise elution conditions were determined based on the relationship between the distribution coefficient and the salt concentration.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.