Abstract

A new method was optimized for rapid screening of 17β-estradiol (E2) in water under 10 min. Molecularly imprinted polymer (MIP) particles (325 ± 25 nm) were added in a water sample at pH 5.5 and 20°C to form a suspension. Fluorescence emission from E2 nonspecifically bound onto the MIP particles was first quenched by large gold nanoparticles (43 ± 5 nm). The Stern-Volmer plot was linear, with dynamic quenching constants (K sv) of 2.9 ×104 M−1. Fluorescence emission from E2 specifically bound inside the MIP particles was next quenched by small nitrite anions that easily penetrated the imprinted cavities. The Stern-Volmer plot became nonlinear, with K sv = 2.1 × 102 M−1 and static quenching constant (V) below 1.0 M−1. The difference between these two emission intensities varied as the initial E2 concentration in water, generating a Scatchard calibration curve with R 2 > 0.97 from 0.1 to 10 ppb.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.