ABSTRACTTypical ozone mixing and mass transfer calculations are lumped approaches based on ideal operating conditions and can misrepresent behavior in real-life installations. This article models the effect of local hydrodynamics and mixing on the overall mass transfer of ozone into water with the aid of multiphase computational fluid dynamics (CFD). CFD models were validated with measured data from a pipeline ozone contactor installation which was optimized for more rapid, uniform mixing and mass transfer. Results emphasize the sensitivity of mixing quality to nozzle placement, size, orientation and spacing relative to main pipeline diameter and flows.