Abstract

AbstractIn this investigation, the mixed γ‐GPS/BTSE silane solution for preparing well adhered composite γ‐GPS/BTSE silane film on Q235 carbon steel surface has been successfully optimized by orthogonal test, and the curing process parameters of temperature and time have also been optimized. The results indicate that the optimized hydrolysis parameters for mixed silanes agent solution are as follows: Vethanol/Vwater 3 : 1, Vγ‐GPS/VBTSE 2 : 3, Vsilanes 6 vol.%, pH 4.0 and hydrolysis time 72 h. In addition, the optimized curing condition for composite γ‐GPS/BTSE silane film is 120 °C and 30 min. After immersion in the optimized mixed γ‐GPS/BTSE silanes agent solution and curing under the optimized condition, the prepared composite γ‐GPS/BTSE silane film on Q235 steel surface can have an adhesion strength of 24.52 MPa to underlying steel substrate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.