Abstract

Pd-capped gasochromic metal hydrides can be used as sensing layer in fiber optic hydrogen detectors. Using a sensing layer consisting of a 50 nm thick Mg 70Ti 30 film capped with a 30 nm Pd catalytic layer we demonstrate a drop in reflectance by a factor of 10, at hydrogen levels down to 10% of the lower flammability limit. The switching takes place within a few seconds, depending on the actual amount of hydrogen in the vicinity of the detector. We report on the sensitivity of the fiber optic detector for hydrogen, both in argon and oxygen rich environments. We further show that the sensing behavior in oxygen rich gas mixtures and in normal air can be improved by adding silver to the catalytic Pd cap layer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.