Abstract

Abstract Aim A lymphoscintigraphy is a crucial diagnostic tool for visualizing lymph nodes. This scan plays a significant role in determining the treatment and recovery plan for the patients. Due to the small lymph node size, obtaining high-quality images is important to prevent inaccurate results. We aimed to identify the most effective method for enhancing image quality through postprocessing techniques and altering the image reconstruction process. Methods Two data sets were utilized in this study. First, National Electrical Manufacturers Association body phantom was filled with [99mTc]Tc-pertechnetate and prepared with and without any activity in the background of the body. Second, the images of 50 patients who underwent single-photon emission computed tomography/computed tomography imaging received [99mTc]Tc-phytate were collected. Discovery 670 GE gamma camera was used for imaging. Preprocessing of all images was performed by Xeleris and 3DSlicer 5.2.2 software was used for quantification. The effect of image reconstruction parameters such as resolution recovery (RR) algorithm, iteration, subsets, cutoff, and power in Butterworth filter, and full width at half maximum (FWHM) of Gaussian filter was assessed. The image quality index was determined based on contrast-to-noise ratio (CNR), contrast, and coefficient of variation. Results The utilization of the RR algorithm showed notable improvements equal to 74, 35, and 38% of CNR, contrast, and noise reduction, respectively. Significant differences were observed in subiteration of 40 to 112 (p-value < 0.05). The alteration of effective parameters in both smoothing filters yielded statistically significant results, leading to enhanced detectability, reduced noise, and improved contrast simultaneously. Optimum results in terms of noise reduction and CNR were achieved with subiteration (i × s) 4 × 12 using a Gaussian filter with FWHM of 4 or Butterworth filter with power of 10 and cutoff of 1. The highest contrast was observed at subiteration 40 using the Butterworth filter with cutoff of 0.5 and power of 5 or Gaussian filter with 2 mm FWHM. Qualitative analysis by two nuclear medicine specialists validated the quantified image quality. Conclusion The reconstruction setting involving subiteration 48 with the Butterworth filter using cutoff of 1 and power of 10 or 4 mm FWHM of Gaussian filter produced the highest quality images.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.