Abstract

This article considers an experimental study of Taguchi’s parameters design to maximize the corrosion resistance of electroless Ni-P-nano-TiO2 on low carbon steel substrate. The experiments were carried out based on Taguchi’s L9 orthogonal array considering four coating parameters of three levels each namely, Bath Temperature, pH of bath, Bath Loading, and concentration of TiO2. Scanning Electron Microscope (SEM) equipped with Energy Dispersive X-ray Spectroscopy (EDS) facilitated the study of the surface morphology and the chemical composition of the coatings. Corrosion performance of the deposits was evaluated by Tafel polarization technique in 3.5 wt. % of NaCl solution. The observation shows that pH level has more significant influence on the corrosion behavior of the composite deposit. The experimental study revealed that the optimum conditions are A3B3C2D1 (Temperature of 88° C, pH of 6, bath loading of 0.5 dm2/l, and TiO2 concentration of 2 g/l).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.