Abstract
In the present paper methods of minimizing or maximizing the values of the Corona onset voltage and the Corona current in small rod-plate air gaps are investigated. The geometry and the way of grounding and charging the electrodes, (Ground Effect), the gap length, the existence of barrier in the gap (Barrier Effect), and the conditions of the air in the gap, are some factors, which influence greatly the distribution of the electric field in the gap, and hence the above values. Combining experimental and simulation-theoretical work, it is resulted that: a) the electrode chosen to be ground, strongly influences the distribution of the field and hence the Corona onset voltage and the corona current in rod-plate air gaps. When the rod is grounded the value of the corona onset voltage is higher and the corona current is significantly smaller. b) A dielectric barrier, when placed in specific positions in the gap, increases the Corona onset voltage to a maximum value, and annihilates the Corona Current.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.