Abstract

The study of various control methods for variable-frequency drives of powerful synchronous motors is performed and an effective limitation of starting current is shown in comparison with direct and soft starts. Simplified models of scalar and vector control systems for variable frequency drive have been developed for calculations of unified and autonomous power systems and their parameters have been optimized. Based on transient calculations, it is proved that application of frequency-controlled drive allows to achieve required limitation of starting motor current and at the same time develop a sufficient starting torque, including under load, in the conditions of large gas condensate field power supply. The features of starting characteristics of synchronous motors with various load functions (constant, quadratic, etc.) are shown.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.