Abstract

Equations for the flow rate, load capacity, and friction torque for a conical hydrostatic bearing were developed. These equations were solved by a digital computer program to determine bearing configurations for minimum friction torque. Design curves are presented that show optimal bearing dimensions for minimum friction torque as a function of dimensionless flow rate for a range of dimensionless load capacity. Results are shown for both laminar and turbulent flow conditions. The results indicate the hydrostatic pocket friction is a significant portion of the total friction torque. However, the bearing dimensions for a minimum friction design are affected very little by inclusion of pocket friction in the analysis. For laminar flow the values of the outerland radius ratio X3 and outer bearing radius ratio X4 did not change significantly with increasing friction factor. For turbulent flow, the outer bearing radius ratio X4 did not change with increasing friction factor; therefore, the value determined for X4 in the laminar flow case is valid for all turbulent flows.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.